What should i do if the ac unit in the attic is leaking water.
Air conditioning unit in attic leaking water.
When the coil melts water overflows the drain pan.
And like stated above a thawing unit can cause leaking water.
The inside unit s blower pulls in hot humid air through the return grille and over the inside unit s cold evaporator coil pictured above to cool the air down.
You can call a professional or try to do it yourself.
Call us to set up a service call and we will stop the leak before it gets larger.
Have drain pan shutoff switch installed and equip it with a float.
Doing this every few months will kill any.
This humidity is left behind in the form of condensation on the coils.
The drain pipe is clogged a clogged drain pipe is the most common cause of standing water in the drain pan.
It should have a piece of pipe sticking up at a 90 degree angle.
Then make sure it does not happen again.
Low refrigerant could be the sign of a refrigerant leak in your hvac unit.
Ensure ac unit is installed with a safety pan to catch overflow.
You ll notice you re low on refrigerant when.
As air passes over the evaporator coils in your air conditioner it cools down and loses some of its humidity.
A low refrigerant level can also cause your unit to freeze.
Locate the pvc pipe near your air handler s drain pan.
Why water forms in a central air conditioner indoor unit part of your air conditioner s job is to pull humidity from the air.
Get an annual air conditioning tune up this annual service should be performed by a professional that can check for problems such as clogs in your condensate drain line.
Before pondering the reason turn off the ac thermostat and mop up the water to prevent problems with mold and rot.
Ensure that the central ac system is installed using a secondary drain line more so if the unit is in the attic.
The following tips can be used for reducing the chances of water damages.
The air conditioner isn t cooling well.
If you already have water leaking from your ceiling call a professional air conditioning repair technician immediately to flush out your condensate drain line or replace the drain pan.
The air handler itself should have a secondary drain pan installed under the air handler in case if the air handler leaks then the secondary drain pan will catch the condensate and take it to another drain.
You hear a hissing or bubbling noise indicating a refrigerant leak depending on the severity of the refrigerant leak you ll either repair the leak or replace the whole ac unit.